82000 Owner’s ManualWARNING SIGNEach spa has been provided with a warning sign which outlines safetyprecautions. This sign should be permanently plac

Seite 3

92000 Owner’s ManualCongratulations! You have purchased one of the finest portable spasavailable. Take the time to read these instructions carefully.

Seite 4 - (CSA SAFETY INFORMATION)

102000 Owner’s ManualAdditional features of the Chairman II, Diplomat, Chairman,Californian, Nautilus, Aurora II and Triad II:• Scrolling Message Cent

Seite 5 - SAVE THESE INSTRUCTIONS

112000 Owner’s ManualNECKFLEX JET PILLOWThe NeckFlex Jet Pillow offers five height adjustable positions to accom-modate different body sizes. The sta

Seite 6

122000 Owner’s Manualbeing ozonated and returned to the spa. During the process, the Silver(Ag) residual is put into the water, which acts as a bacte

Seite 7

132000 Owner’s ManualBEFORE ATTEMPTING TO HOOK-UP OR USE YOUR SPA,PLEASE READ THROUGH THESE INSTRUCTIONS ANDCAREFULLY VIEW YOUR VIDEO OWNER’S MANUAL.P

Seite 8

142000 Owner’s ManualELECTRICAL HOOK -UP INSTRUCTIONSNOTE: Do not turn on electrical power to your spa until told to doso later in this manual.Have a

Seite 9

152000 Owner’s ManualELECTRICAL REQUIREMENT CHARTTo hook-up your spa, follow these instructions:Model Branch Cir. GaugeC h a i rman II 2 4 0 V, 38A 3

Seite 10 - WARNING SIGN

162000 Owner’s Manual1) Remove the screws holding the equipment access panel to the frontof the spa cabinet and set the panel aside.2) Loosen the four

Seite 11 - SPA FEATURES

172000 Owner’s Manual1) Before filling your spa, install the hose bib that is included in theowner’s manual packet located in the equipment compartmen

Seite 12 - 2000 Owner’s Manual

Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8Spa Features . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 13

182000 Owner’s Manualand turn the pump(s) on again. Turn the pump(s) on and off severaltimes until the jets function properly.6) When the jets are in

Seite 14

192000 Owner’s ManualAdvanced microprocessor technology has been utilized to produce theProgrammable Digital Control. Easy to use and understand, Dim

Seite 15 - INSTRUCTIONS FOR YOUR SP A

202000 Owner’s ManualTEMPERATURE PADSPushing the UP pad increases the temperature and pushing the DOWNpad decreases the temperature. Push the respect

Seite 16 - HOOK-UP INSTRUCTIONS

212000 Owner’s ManualWhen the desired number is displayed, push the LIGHT pad to acceptthe selection and change the flashing number to the “minute” pl

Seite 17 - ELECTRICAL REQUIREMENT CHART

222000 Owner’s ManualNUMBER OF FILTER CYCLESTo adjust the number of filter cycles per day, push the UP or DOWN padto cycle through the number of filte

Seite 18

232000 Owner’s Manual3) A flow switch has malfunctioned. The spa will operate but theheater will not activate. Contact your local Authorized Dimensi

Seite 19 - AURORA HP , INTERLUDE, ARENA

242000 Owner’s Manual1) Before filling your spa, install the black plastic hose bib that isincluded in the owner’s manual packet located in the equipm

Seite 20

252000 Owner’s Manual7) When the jets are in full operation, close the bleeder valve and pushthe UP pad until the desired spa temperature is indicated

Seite 21 - THE PROGRAMMABLE DIGIT AL

262000 Owner’s ManualAdvanced microprocessor technology has been utilized to produce theScrolling Message Center. The most technologically advanced s

Seite 22

272000 Owner’s ManualNOTE: Pushing either JETS control pad will disable any concurrent fil-ter cycle. LIGHT CONTROL: Push the LIGHT control pad once

Seite 23

12000 Owner’s ManualWhen installing and using this electrical equipment, basic safetyprecautions should always be followed, including: 1) WARNING: To

Seite 24

282000 Owner’s ManualLIQUID CRYSTAL DISPLAY:The LCD continuously shows the operating status of the spa, as well asthe various monitoring functions, se

Seite 25

292000 Owner’s ManualFILTER CYCLE START TIME After setting the time-of-day, the top line of the LCD will read “SETFILTER CYCLE TIME”. Push the UP or

Seite 26 - TRIAD II AND A URORA II

302000 Owner’s ManualPUMP RUN TIMEAfter setting the number of filter cycles, the top line of the LCD will re a d“SET PUMP RUN TIME”. Push the UP or

Seite 27

312000 Owner’s ManualTo lock the panel all the following pads must be pushed within 3 sec-onds:1) Push the Dimension One Spas ICON (logo) pad.2) Push

Seite 28 - THE SCROLLING MESSAGE CENTER

322000 Owner’s ManualCONTROL PANEL RESETThis function is used to completely reset the clock and all other systemvariables to the factory defaults. Pl

Seite 29

332000 Owner’s ManualCHANGE WATEREvery four months the top line of your LCD will read “CHANGEWATER” and the message “TURN POWER OFF, DRAIN & REFIL

Seite 30

342000 Owner’s ManualDIAGNOSTIC MESSAGESOVERHEATWhen “OVERHEAT” along with the water temperature of the spa, isdisplayed on the LCD, the spa is in a h

Seite 31

352000 Owner’s ManualHIGH LIMIT SENSORWhen “HIGH LIMIT SENSOR” is displayed on the LCD, the high limitsensor is non-functional. Contact your local Au

Seite 32

362000 Owner’s ManualMaintaining proper water chemistry is imperative to maintaining safewater and preventing possible damage to your spa components.

Seite 33

372000 Owner’s ManualWe strongly recommend that you buy your chemicals from your localAuthorized Dimension One Spas dealer. Your local Authorized dea

Seite 34

22000 Owner’s Manual7) ELECTRICAL SUPPLY: The electrical supply for this spa mustinclude a suitably rated switch or circuit breaker to open allu n g

Seite 35

382000 Owner’s ManualBROMINE (BROMINE CANNOT BE USED WITH THE VISIONSYSTEMS)Bromine is the most common sanitizer used in spas. Bacteria can becontrol

Seite 36 - DIAGNOSTIC MESSAGES

392000 Owner’s ManualNOTE: Two individuals in a spa may use as much as 3 ppm of chlorinein 20 minutes. SHOCK TREATMENT (POTASSIUM PEROXYMONOSULFATE)E

Seite 37

402000 Owner’s Manualdraining and refilling). This will suspend any metals in your water andincrease the life of your spa equipment.TOTAL ALKALINITYT

Seite 38 - WATER CHEMISTR Y

412000 Owner’s ManualDRAINING YOUR SPAAll Dimension One spas are gravity drained. Do not drain water ontoyour lawn or plants unless all of the bromin

Seite 39

422000 Owner’s Manualassembly and the access lid or cover. After cleaning, run the pump for afew minutes at high speed, then return to the heating mo

Seite 40

432000 Owner’s ManualAuthorized Dimension One Dealer can recommend a good product forthis use. Be careful when using detergents not to leave soap res

Seite 41

442000 Owner’s ManualIf you decide to drain the spa, drain it as completely as possible. Youmay wish to tilt the spa on edge and use a wet-vac or hig

Seite 42

452000 Owner’s Manual1) Equipment failure due to improper/inadequate electrical service. Allsystems require dedicated circuits as described in this m

Seite 43 - CARE FOR YOUR SP A

46Troubleshooting1. Spa will not come onin any mode2. Spa does not heat3. Pulsating jets4. Poor jet action or nojet action5. Spa temperatureerratic6.

Seite 44

47Glossary of TermsBLEEDER VALVE - A small valve used to relieve or expel air fromthe spa’s plumbing or pump.CIRCULATION PUMP - A small pump that circ

Seite 45

32000 Owner’s ManualGrounding, or the symbol * is located inside the supply terminalbox or compartment. To reduce the risk of electric shock, th

Seite 46

48Wiring DiagramWIRING DIAGRAM

Seite 47

42000 Owner’s ManualDEVRAIENT CONSULTER UN MÉDECIN AVANT D’UTILISERUSE CUVE DE RELAXATION.WARNING : People with infectious diseases should not use a s

Seite 48 - PROBLEM DIAGNOSIS ACTION

52000 Owner’s ManualWARNING: Before entering the spa or hot tub, measure the watertemperature with an accurate thermometer.AVERTISSEMENT: AVANT D’UTIL

Seite 49 - GLOSSARY OF TERMS

62000 Owner’s ManualHyperthermia occurs when the internal temperature of the body reachesa level several degrees above the normal body temperature of

Seite 50 - WIRING DIAGRAM

72000 Owner’s Manual4) Do not use the spa under the influence of alcohol, narcotics, or otherdrugs. Use of the spa under these conditions may lead to